КАТЕГОРИИ: Архитектура-(3434)Астрономия-(809)Биология-(7483)Биотехнологии-(1457)Военное дело-(14632)Высокие технологии-(1363)География-(913)Геология-(1438)Государство-(451)Демография-(1065)Дом-(47672)Журналистика и СМИ-(912)Изобретательство-(14524)Иностранные языки-(4268)Информатика-(17799)Искусство-(1338)История-(13644)Компьютеры-(11121)Косметика-(55)Кулинария-(373)Культура-(8427)Лингвистика-(374)Литература-(1642)Маркетинг-(23702)Математика-(16968)Машиностроение-(1700)Медицина-(12668)Менеджмент-(24684)Механика-(15423)Науковедение-(506)Образование-(11852)Охрана труда-(3308)Педагогика-(5571)Полиграфия-(1312)Политика-(7869)Право-(5454)Приборостроение-(1369)Программирование-(2801)Производство-(97182)Промышленность-(8706)Психология-(18388)Религия-(3217)Связь-(10668)Сельское хозяйство-(299)Социология-(6455)Спорт-(42831)Строительство-(4793)Торговля-(5050)Транспорт-(2929)Туризм-(1568)Физика-(3942)Философия-(17015)Финансы-(26596)Химия-(22929)Экология-(12095)Экономика-(9961)Электроника-(8441)Электротехника-(4623)Энергетика-(12629)Юриспруденция-(1492)Ядерная техника-(1748) |
Operating the Ozone Generator Air Purifier
(Front View)
Timer Control Knob Turn clockwise to set the timer for timed operation up to TWO hours. Turn counterclockwise to set “HOLD” function Ozone Adjuster for option from 0-5000 mg per hour Indicator Light Illuminates when unit is in operation. Ozone Nozzel Connect the ozone output and the silicone tube (Back View)
The Ozone generator is designed to use in unoccupied spaces. It has a timer that will enable it to run for a maximum duration of 2 hours. The timer will then shut the commercial air purifier off. You should allow 40 minutes before returning to the treated area. To operate the Ozone Generator: Ø The device should be placed something under the unit bottom for steady. Ø Connect the ozone output nozzle and the silicone tube(the silicone tube shall be flowed) Ø Close off the desired area to be treated. Ø Remove all occupants and pets. Ø Position the unit as close as possible to the odor source. Ø In such environments as motels that have individual heating and cooling systems, turn the fan on and set on re-circulate. Ø Set timer to desired time and leave the room. Ø Allow 40 minutes before re-entering the treated space. Ø Return to space & ventilation area.
If you suspect a problem with your unit check the following:
1) Unit is plugged in properly.
2) It’s important that the Ozone Generator Commercial air purifier be properly grounded to avoid potential shock. 3) Check the fan if it is working and the ozone output if there is gas.
4) Fuse is installed properly and in good condition. To replace fuse, pull out the plastic fuse holder, remove old fuse and insert new fuse. Replacement fuse must be 1 amp (0.79 inch). Refer to picture as follows:
The ozone generator commercial air purifier comes with a 3 Year Limited Warranty.
2) Users normal use of the product in accordance with the instruction manual, the failure of the warranty period, can be a free repair.
Дата добавления: 2014-12-24; Просмотров: 356; Нарушение авторских прав?; Мы поможем в написании вашей работы! Нам важно ваше мнение! Был ли полезен опубликованный материал? Да | Нет |